บริษัท ทริปเปิ้ล อี เทรดดิ้ง จำกัด

EP MVS CB 4000A 65kA 3P MF ET2 fixed manual circuit breaker MVS40H3MF2L

฿144900.00
EasyPact MVS40 is a 4000A circuit breaker. The application is suitable for 690V AC@50/60Hz. With manually operating mechanism(ACB/SD), and basic trip unit with display. It provides basic protection(LI
เหลือ 100 ชิ้น
ซื้อเลย
หยิบลงตะกร้า
  • หมวดหมู่ : SCHNEIDER
  • รหัสสินค้า : sc-00030

รายละเอียดสินค้า EP MVS CB 4000A 65kA 3P MF ET2 fixed manual circuit breaker MVS40H3MF2L

Main
RangeEasyPact
Product nameMVS40H
Device short nameMVS40H
Product or component typeCircuit breaker
Device applicationDistribution
Poles description3P
Protected poles description3P 3d
[In] rated current4000 A at 40 °C
Network typeAC
[Ue] rated operational voltage690 V AC 50/60 Hz conforming to IEC 60947-2
Breaking capacity codeH
Suitability for isolationYes conforming to IEC 60947-2
Utilisation categoryCategory B
Trip unit nameET2I
Trip unit technologyElectronic
Trip unit rating4000 A
Complementary
Network frequency50/60 Hz
Control typeManually operated
Mounting modeFixed
Mounting supportBase plate
Rail
Connection positionHorizontal
Vertical
Location of connectionRear
[Ui] rated insulation voltage1000 V AC 50/60 Hz conforming to IEC 60947-2
[Uimp] rated impulse withstand voltage12 kV conforming to IEC 60947-2
Circuit breaker CT rating4000 A
Breaking capacity65 kA Icu at 220...440 V AC 50/60 Hz conforming to IEC 60947-2
[Ics] rated service breaking capacity65 kA (Ics) at 220...440 V AC 50/60 Hz conforming to IEC 60947-2
50 kA (Ics) at 690 V AC 50/60 Hz conforming to IEC 60947-2
Mechanical durability20000 cycles (with maintenance) conforming to IEC 60947-2
10000 cycles (without maintenance) conforming to IEC 60947-2
Electrical durabilityCategory B: 5000 cycles 440 V AC 50/60 Hz without maintenance conforming to IEC 60947-2
Category B: 2500 cycles 690 V AC 50/60 Hz without maintenance conforming to IEC 60947-2
Connection pitch115 mm without spreader
Contact position indicatorYes
[Icm] rated short-circuit making capacity143 kA (Icm) at 220...440 V AC 50/60 Hz conforming to IEC 60947-2
[Icw] rated short-time withstand current65 kA (1 s) at 220...440 V AC 50/60 Hz conforming to IEC 60947-2
50 kA (1 s) at 690 V AC 50/60 Hz conforming to IEC 60947-2
50 kA (3 s) at 440/690 V AC 50/60 Hz conforming to IEC 60947-2
Trip unit protection functionsLI
Protection typeInstantaneous short-circuit protection
Overload protection (long time)
Fault indicationShort-circuit
Internal fault
Overload
Long time pick-up adjustment type IrAdjustable 9 settings
Long time pick-up adjustment range0.4...1 x In
Long time delay adjustment typeAdjustable 9 settings
[tr] long-time delay adjustment range0.5…24 s at 6 x Ir
Thermal memory20 minutes before and after tripping
Instantaneous pick-up adjustment type IiAdjustable 9 settings
Instantaneous pick-up adjustment range1.5...10 x Ir
Zone selective interlocking ZSIWith
Current sensor rating range1000/4000 A
Maximum breaking time25 ms
Maximum closing response time70 ms
Height352 mm
Width422 mm
Depth297 mm
Net weight60 kg
Environment
StandardsIEC 60947-2
Product certificationsCCC
CCS
GOST
IEC
Pollution degree4 conforming to IEC 60664-1
IP degree of protectionIP40
Ambient air temperature for operation-5…70 °C
Ambient air temperature for storage-40…85 °C without control unit
-25…85 °C with control unit
Packing Units
Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height42.0 cm
Package 1 Width35.0 cm
Package 1 Length50.0 cm
Package 1 Weight53.5 kg
Contractual warranty
Warranty18 months