Circuit breaker, EasyPact MVS, 3 Poles, 3200A, 50kA, MDO, ETA2, drawout, manual MVS32N3MW2A

฿128520.00
EasyPact MVS32N is a 3200A circuit breaker. The breaking capacity (Icu) is 50kA rms at 440VAC 50/60Hz. The operational voltage is 690VAC. This version is 3 poles drawout. Electronic trip unit provides
เหลือ 100 ชิ้น
ซื้อเลย
หยิบลงตะกร้า
  • หมวดหมู่ : SCHNEIDER
  • รหัสสินค้า : SC-00071

รายละเอียดสินค้า Circuit breaker, EasyPact MVS, 3 Poles, 3200A, 50kA, MDO, ETA2, drawout, manual MVS32N3MW2A

Main
RangeEasyPact
Product nameMVS32N
Device short nameMVS32N
Product or component typeCircuit breaker
Device applicationDistribution
Poles description3P
Protected poles description3P 3d
[In] rated current3200 A at 40 °C
Network typeAC
[Ue] rated operational voltage690 V AC 50/60 Hz conforming to IEC 60947-2
Breaking capacity codeN
Suitability for isolationYes conforming to IEC 60947-2
Utilisation categoryCategory B
Trip unit nameETA2I
Trip unit technologyElectronic
Trip unit rating3200 A
Complementary
Network frequency50/60 Hz
Control typeManually operated
Mounting modeDrawout
Mounting supportRail
Base plate
Connection positionVertical
Horizontal
Location of connectionRear
[Ui] rated insulation voltage1000 V AC 50/60 Hz conforming to IEC 60947-2
[Uimp] rated impulse withstand voltage12 kV conforming to IEC 60947-2
Circuit breaker CT rating3200 A
Breaking capacity50 kA Icu at 220...440 V AC 50/60 Hz conforming to IEC 60947-2
[Ics] rated service breaking capacity50 kA (Ics) at 220...440 V AC 50/60 Hz conforming to IEC 60947-2
Mechanical durability20000 cycles (with maintenance) conforming to IEC 60947-2
10000 cycles (without maintenance) conforming to IEC 60947-2
Electrical durabilityCategory B: 5000 cycles 440 V AC 50/60 Hz without maintenance conforming to IEC 60947-2
Category B: 2500 cycles 690 V AC 50/60 Hz without maintenance conforming to IEC 60947-2
Connection pitch115 mm without spreader
Contact position indicatorYes
[Icm] rated short-circuit making capacity105 kA (Icm) at 220...440 V AC 50/60 Hz conforming to IEC 60947-2
[Icw] rated short-time withstand current50 kA (1 s) at 220...440 V AC 50/60 Hz conforming to IEC 60947-2
42 kA (1 s) at 690 V AC 50/60 Hz conforming to IEC 60947-2
25 kA (3 s) at 440/690 V AC 50/60 Hz conforming to IEC 60947-2
Trip unit protection functionsLI
Protection typeOverload protection (long time)
Instantaneous short-circuit protection
Fault indicationInternal fault
Overload
Short-circuit
Long time pick-up adjustment type IrAdjustable 9 settings
Long time pick-up adjustment range0.4...1 x In
Long time delay adjustment typeAdjustable 9 settings
[tr] long-time delay adjustment range0.5…24 s at 6 x Ir
Thermal memory20 minutes before and after tripping
Instantaneous pick-up adjustment type IiAdjustable 9 settings
Instantaneous pick-up adjustment range1.5...10 x Ir
Zone selective interlocking ZSIWith
Display typeDigital display
Type of measurementCurrent
Current sensor rating range1000/4000 A
Maximum breaking time25 ms
Maximum closing response time70 ms
Height439 mm
Width441 mm
Depth395 mm
Net weight90 kg
Environment
StandardsIEC 60947-2
Product certificationsCCC
CCS
GOST
IEC
Pollution degree4 conforming to IEC 60664-1
IP degree of protectionIP40
Ambient air temperature for operation-5…70 °C
Ambient air temperature for storage-40…85 °C without control unit
-25…85 °C with control unit
Packing Units
Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height42.0 cm
Package 1 Width35.0 cm
Package 1 Length50.0 cm
Package 1 Weight38.0 kg
Contractual warranty
Warranty18 months

Environmental Data

Schneider Electric aims to achieve Net Zero status by 2050 through supply chain partnerships, lower impact materials, and circularity via our ongoing “Use Better, Use Longer, Use Again” campaign to extend product lifetimes and recyclability.
Environmental footprint