บริษัท ทริปเปิ้ล อี เทรดดิ้ง จำกัด

Circuit breaker, EasyPact MVS, 3 Poles, 4000A, 50kA, MDO, ETA2, drawout, manual MVS40N3MW2A

฿188580.00
EasyPact MVS40N is a 4000A circuit breaker. The breaking capacity (Icu) is 50kA rms at 440VAC 50/60Hz. The operational voltage is 690VAC. This version is 3 poles drawout. Electronic trip unit provides
เหลือ 100 ชิ้น
ซื้อเลย
หยิบลงตะกร้า
  • หมวดหมู่ : SCHNEIDER
  • รหัสสินค้า : SC-00072

รายละเอียดสินค้า Circuit breaker, EasyPact MVS, 3 Poles, 4000A, 50kA, MDO, ETA2, drawout, manual MVS40N3MW2A

Main
RangeEasyPact
Product nameMVS40N
Device short nameMVS40N
Product or component typeCircuit breaker
Device applicationDistribution
Poles description3P
Protected poles description3P 3d
[In] rated current4000 A at 40 °C
Network typeAC
[Ue] rated operational voltage690 V AC 50/60 Hz conforming to IEC 60947-2
Breaking capacity codeN
Suitability for isolationYes conforming to IEC 60947-2
Utilisation categoryCategory B
Trip unit nameETA2I
Trip unit technologyElectronic
Trip unit rating4000 A
Complementary
Network frequency50/60 Hz
Control typeManually operated
Mounting modeDrawout
Mounting supportRail
Base plate
Connection positionHorizontal
Vertical
Location of connectionRear
[Ui] rated insulation voltage1000 V AC 50/60 Hz conforming to IEC 60947-2
[Uimp] rated impulse withstand voltage12 kV conforming to IEC 60947-2
Circuit breaker CT rating4000 A
Breaking capacity55 kA Icu at 220...440 V AC 50/60 Hz conforming to IEC 60947-2
[Ics] rated service breaking capacity55 kA (Ics) at 220...440 V AC 50/60 Hz conforming to IEC 60947-2
Mechanical durability20000 cycles (with maintenance) conforming to IEC 60947-2
10000 cycles (without maintenance) conforming to IEC 60947-2
Electrical durabilityCategory B: 5000 cycles 440 V AC 50/60 Hz without maintenance conforming to IEC 60947-2
Category B: 2500 cycles 690 V AC 50/60 Hz without maintenance conforming to IEC 60947-2
Connection pitch115 mm without spreader
Contact position indicatorYes
[Icm] rated short-circuit making capacity121 kA (Icm) at 220...440 V AC 50/60 Hz conforming to IEC 60947-2
[Icw] rated short-time withstand current42 kA (1 s) at 690 V AC 50/60 Hz conforming to IEC 60947-2
55 kA (1 s) at 220...440 V AC 50/60 Hz conforming to IEC 60947-2
30 kA (3 s) at 440/690 V AC 50/60 Hz conforming to IEC 60947-2
Trip unit protection functionsLI
Protection typeInstantaneous short-circuit protection
Overload protection (long time)
Fault indicationOverload
Internal fault
Short-circuit
Long time pick-up adjustment type IrAdjustable 9 settings
Long time pick-up adjustment range0.4...1 x In
Long time delay adjustment typeAdjustable 9 settings
[tr] long-time delay adjustment range0.5…24 s at 6 x Ir
Thermal memory20 minutes before and after tripping
Instantaneous pick-up adjustment type IiAdjustable 9 settings
Instantaneous pick-up adjustment range1.5...10 x Ir
Zone selective interlocking ZSIWith
Display typeDigital display
Type of measurementCurrent
Current sensor rating range1000/4000 A
Maximum breaking time25 ms
Maximum closing response time70 ms
Height439 mm
Width441 mm
Depth395 mm
Net weight90 kg
Environment
StandardsIEC 60947-2
Product certificationsCCC
IEC
CCS
GOST
Pollution degree4 conforming to IEC 60664-1
IP degree of protectionIP40
Ambient air temperature for operation-5…70 °C
Ambient air temperature for storage-40…85 °C without control unit
-25…85 °C with control unit
Packing Units
Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height42.0 cm
Package 1 Width35.0 cm
Package 1 Length50.0 cm
Package 1 Weight38.0 kg
Contractual warranty