บริษัท ทริปเปิ้ล อี เทรดดิ้ง จำกัด

Circuit breaker, GoPact MCCB 800, 3 poles, 70kA at 415VAC, 500A rating, TMD trip unit, adjustable th

฿18360.00
This product is part of the new GoPact Molded Case Circuit Breakers range (MCCB). It is a complete 3 poles circuit breaker made of a 800A breaker frame and of a thermal magnetic trip unit (TMD). GoPac
เหลือ 100 ชิ้น
ซื้อเลย
หยิบลงตะกร้า
  • หมวดหมู่ : SCHNEIDER
  • รหัสสินค้า : SC-000211

รายละเอียดสินค้า Circuit breaker, GoPact MCCB 800, 3 poles, 70kA at 415VAC, 500A rating, TMD trip unit, adjustable th

80 kA Icu at 220/230 V AC 50/60 Hz conforming to EN/IEC 60947-2","externalUrl":null,"beforeText":null,"afterText":null}]},{"characteristicName":"Performance level","characteristicValues":[{"needUpperCase":true,"displayLinkIcon":false,"labelText":"H 70 kA 380/415 V AC","externalUrl":null,"beforeText":null,"afterText":null}]},{"characteristicName":"Trip unit name","characteristicValues":[{"needUpperCase":true,"displayLinkIcon":false,"labelText":"TM-D","externalUrl":null,"beforeText":null,"afterText":null}]},{"characteristicName":"Trip unit technology","characteristicValues":[{"needUpperCase":true,"displayLinkIcon":false,"labelText":"Thermal-magnetic","externalUrl":null,"beforeText":null,"afterText":null}]},{"characteristicName":"Trip unit protection functions","characteristicValues":[{"needUpperCase":true,"displayLinkIcon":false,"labelText":"LI","externalUrl":null,"beforeText":null,"afterText":null}]},{"characteristicName":"Control type","characteristicValues":[{"needUpperCase":true,"displayLinkIcon":false,"labelText":"Toggle","externalUrl":null,"beforeText":null,"afterText":null}]},{"characteristicName":"Circuit breaker mounting mode","characteristicValues":[{"needUpperCase":true,"displayLinkIcon":false,"labelText":"Fixed","externalUrl":null,"beforeText":null,"afterText":null}]}]},{"tableName":"Complementary","rows":[{"characteristicName":"[Ui] rated insulation voltage","characteristicValues":[{"needUpperCase":true,"displayLinkIcon":false,"labelText":"440 V AC conforming to EN/IEC 60947-2","externalUrl":null,"beforeText":null,"afterText":null}]},{"characteristicName":"[Uimp] rated impulse withstand voltage","characteristicValues":[{"needUpperCase":true,"displayLinkIcon":false,"labelText":"8 kV conforming to EN/IEC 60947-2","externalUrl":null,"beforeText":null,"afterText":null}]},{"characteristicName":"[Ics] rated service short-circuit breaking capacity","characteristicValues":[{"needUpperCase":true,"displayLinkIcon":false,"labelText":"70 kA at 380/415 V AC 50/60 Hz conforming to EN/IEC 60947-2
80 kA at 220/230 V AC 50/60 Hz conforming to EN/IEC 60947-2","externalUrl":null,"beforeText":null,"afterText":null}]},{"characteristicName":"Mechanical durability","characteristicValues":[{"needUpperCase":true,"displayLinkIcon":false,"labelText":"15000 cycles","externalUrl":null,"beforeText":null,"afterText":null}]},{"characteristicName":"Electrical durability","characteristicValues":[{"needUpperCase":true,"displayLinkIcon":false,"labelText":"3000 cycles at 415 V In","externalUrl":null,"beforeText":null,"afterText":null}]},{"characteristicName":"Power dissipation per pole","characteristicValues":[{"needUpperCase":true,"displayLinkIcon":false,"labelText":"60 W","externalUrl":null,"beforeText":null,"afterText":null}]},{"characteristicName":"Mounting support","characteristicValues":[{"needUpperCase":true,"displayLinkIcon":false,"labelText":"Backplate","externalUrl":null,"beforeText":null,"afterText":null}]},{"characteristicName":"Mounting position","characteristicValues":[{"needUpperCase":true,"displayLinkIcon":false,"labelText":"Horizontal and vertical
Flat on the back","externalUrl":null,"beforeText":null,"afterText":null}]},{"characteristicName":"Upside connection","characteristicValues":[{"needUpperCase":true,"displayLinkIcon":false,"labelText":"Front","externalUrl":null,"beforeText":null,"afterText":null}]},{"characteristicName":"Downside connection","characteristicValues":[{"needUpperCase":true,"displayLinkIcon":false,"labelText":"Front","externalUrl":null,"beforeText":null,"afterText":null}]},{"characteristicName":"Connection terminals","characteristicValues":[{"needUpperCase":true,"displayLinkIcon":false,"labelText":"screw terminals","externalUrl":null,"beforeText":null,"afterText":null}]},{"characteristicName":"Connection pitch","characteristicValues":[{"needUpperCase":true,"displayLinkIcon":false,"labelText":"60 mm","externalUrl":null,"beforeText":null,"afterText":null}]},{"characteristicName":"Protection type","characteristicValues":[{"needUpperCase":true,"displayLinkIcon":false,"labelText":"L : for overload protection (thermal)
I : for short-circuit protection (magnetic)","externalUrl":null,"beforeText":null,"afterText":null}]},{"characteristicName":"Trip unit rating","characteristicValues":[{"needUpperCase":true,"displayLinkIcon":false,"labelText":"500 A at 40 °C","externalUrl":null,"beforeText":null,"afterText":null}]},{"characteristicName":"Long-time pick-up adjustment type Ir (thermal protection)","characteristicValues":[{"needUpperCase":true,"displayLinkIcon":false,"labelText":"Adjustable","externalUrl":null,"beforeText":null,"afterText":null}]},{"characteristicName":"[Ir] long-time protection pick-up adjustment range","characteristicValues":[{"needUpperCase":true,"displayLinkIcon":false,"labelText":"0.7...1 x In","externalUrl":null,"beforeText":null,"afterText":null}]},{"characteristicName":"Long-time protection delay adjustment type tr","characteristicValues":[{"needUpperCase":true,"displayLinkIcon":false,"labelText":"Fixed","externalUrl":null,"beforeText":null,"afterText":null}]},{"characteristicName":"Instantaneous protection pick-up adjustment type Ii","characteristicValues":[{"needUpperCase":true,"displayLinkIcon":false,"labelText":"Fixed","externalUrl":null,"beforeText":null,"afterText":null}]},{"characteristicName":"[Ii] instantaneous protection pick-up adjustment range","characteristicValues":[{"needUpperCase":true,"displayLinkIcon":false,"labelText":"12 x In","externalUrl":null,"beforeText":null,"afterText":null}]},{"characteristicName":"Width (W)","characteristicValues":[{"needUpperCase":true,"displayLinkIcon":false,"labelText":"180 mm","externalUrl":null,"beforeText":null,"afterText":null}]},{"characteristicName":"Height (H)","characteristicValues":[{"needUpperCase":true,"displayLinkIcon":false,"labelText":"250 mm","externalUrl":null,"beforeText":null,"afterText":null}]},{"characteristicName":"Depth (D)","characteristicValues":[{"needUpperCase":true,"displayLinkIcon":false,"labelText":"105 mm","externalUrl":null,"beforeText":null,"afterText":null}]},{"characteristicName":"Net weight","characteristicValues":[{"needUpperCase":true,"displayLinkIcon":false,"labelText":"6.9 kg","externalUrl":null,"beforeText":null,"afterText":null}]},{"characteristicName":"Colour","characteristicValues":[{"needUpperCase":true,"displayLinkIcon":false,"labelText":"Grey (RAL 7035)","externalUrl":null,"beforeText":null,"afterText":null}]}]},{"tableName":"Environment","rows":[{"characteristicName":"Standards","characteristicValues":[{"needUpperCase":true,"displayLinkIcon":false,"labelText":"EN/IEC 60947-1
EN/IEC 60947-2
EN/IEC 60947-2 Annex H","externalUrl":null,"beforeText":null,"afterText":null}]},{"characteristicName":"Overvoltage category","characteristicValues":[{"needUpperCase":true,"displayLinkIcon":false,"labelText":"III","externalUrl":null,"beforeText":null,"afterText":null}]},{"characteristicName":"Pollution degree","characteristicValues":[{"needUpperCase":true,"displayLinkIcon":false,"labelText":"3 conforming to IEC 60664-1","externalUrl":null,"beforeText":null,"afterText":null}]},{"characteristicName":"IP degree of protection","characteristicValues":[{"needUpperCase":true,"displayLinkIcon":false,"labelText":"IP20 conforming to IEC 60529","externalUrl":null,"beforeText":null,"afterText":null}]},{"characteristicName":"Ambient air temperature for operation","characteristicValues":[{"needUpperCase":true,"displayLinkIcon":false,"labelText":"-20…55 °C","externalUrl":null,"beforeText":null,"afterText":null}]},{"characteristicName":"Ambient air temperature for storage","characteristicValues":[{"needUpperCase":true,"displayLinkIcon":false,"labelText":"-35…85 °C","externalUrl":null,"beforeText":null,"afterText":null}]},{"characteristicName":"Operating altitude","characteristicValues":[{"needUpperCase":true,"displayLinkIcon":false,"labelText":"0...2000 m without derating
2000...5000 m with derating","externalUrl":null,"beforeText":null,"afterText":null}]}]},{"tableName":"Packing Units","rows":[{"characteristicName":"Unit Type of Package 1","characteristicValues":[{"needUpperCase":true,"displayLinkIcon":false,"labelText":"PCE","externalUrl":null,"beforeText":null,"afterText":null}]},{"characteristicName":"Number of Units in Package 1","characteristicValues":[{"needUpperCase":true,"displayLinkIcon":false,"labelText":"1","externalUrl":null,"beforeText":null,"afterText":null}]},{"characteristicName":"Package 1 Height","characteristicValues":[{"needUpperCase":true,"displayLinkIcon":false,"labelText":"18 cm","externalUrl":null,"beforeText":null,"afterText":null}]},{"characteristicName":"Package 1 Width","characteristicValues":[{"needUpperCase":true,"displayLinkIcon":false,"labelText":"27 cm","externalUrl":null,"beforeText":null,"afterText":null}]},{"characteristicName":"Package 1 Length","characteristicValues":[{"needUpperCase":true,"displayLinkIcon":false,"labelText":"29 cm","externalUrl":null,"beforeText":null,"afterText":null}]},{"characteristicName":"Package 1 Weight","characteristicValues":[{"needUpperCase":true,"displayLinkIcon":false,"labelText":"11050 g","externalUrl":null,"beforeText":null,"afterText":null}]},{"characteristicName":"Unit Type of Package 2","characteristicValues":[{"needUpperCase":true,"displayLinkIcon":false,"labelText":"P06","externalUrl":null,"beforeText":null,"afterText":null}]},{"characteristicName":"Number of Units in Package 2","characteristicValues":[{"needUpperCase":true,"displayLinkIcon":false,"labelText":"12","externalUrl":null,"beforeText":null,"afterText":null}]},{"characteristicName":"Package 2 Height","characteristicValues":[{"needUpperCase":true,"displayLinkIcon":false,"labelText":"105 cm","externalUrl":null,"beforeText":null,"afterText":null}]},{"characteristicName":"Package 2 Width","characteristicValues":[{"needUpperCase":true,"displayLinkIcon":false,"labelText":"60 cm","externalUrl":null,"beforeText":null,"afterText":null}]},{"characteristicName":"Package 2 Length","characteristicValues":[{"needUpperCase":true,"displayLinkIcon":false,"labelText":"80 cm","externalUrl":null,"beforeText":null,"afterText":null}]},{"characteristicName":"Package 2 Weight","characteristicValues":[{"needUpperCase":true,"displayLinkIcon":false,"labelText":"146.392 kg","externalUrl":null,"beforeText":null,"afterText":null}]}]}]" plain-product-characteristics-label="Specifications" plain-show-less-label="Show less specifications" plain-show-more-label="Show more specifications" plain-read-more-label="Read more" plain-read-less-label="Read less" plain-awards-label="Awards" plain-long-desc-sentences="["This product is part of the new GoPact Molded Case Circuit Breakers range (MCCB).","It is a complete 3 poles circuit breaker made of a 800A breaker frame and of a thermal magnetic trip unit (TMD).","GoPact MCCB has a good price-performance ratio for basic applications and delivers a reliable electrical protection for your applications.","The breaking capacity (Icu) is 70kA rms at 415VAC 50/60Hz.","The operational voltage is 415VAC 50/60Hz.","This product embeds a 500A rating (In) thermal-magnetic trip unit (TMD).","This TMD trip unit provides an adjustable thermal protection Ir (against overloads) with a setting range from 0.7xIn to 1xIn (350A-500A).","And it provides a fixed magnetic (against short-circuits) protection set to 12xIn (6000A).","GoPact MCCB comes with a variety of optional accessories simple to choose and to install.","Product dimensions are 180mm (Width) x 250mm (Height) x 105mm (Depth).","The weight is 6.9 kg.","GoPact MCCB 800 is IEC 60947-1 and IEC 60947-2 certified.","GoPact MCCB range benefits from Schneider Electric quality assurance."]" plain-long-desc-sentences-title="Description" plain-description-images="[]" class="hydrated" style="display: block; box-sizing: inherit; overflow-anchor: none; visibility: inherit;">
Main
Range of productGoPact MCCB
Product or component typeCircuit breaker
Product nameGoPact MCCB 800
Device applicationDistribution
Poles description3P
Protected poles description3D
[In] rated current500 A at 40 °C
[Ue] rated operational voltage415 V AC 50/60 Hz conforming to EN/IEC 60947-2
Suitability for isolationYes conforming to EN/IEC 60947-2
Utilisation categoryCategory A
[Icu] rated ultimate short-circuit breaking capacity70 kA Icu at 380/415 V AC 50/60 Hz conforming to EN/IEC 60947-2
80 kA Icu at 220/230 V AC 50/60 Hz conforming to EN/IEC 60947-2
Performance levelH 70 kA 380/415 V AC
Trip unit nameTM-D
Trip unit technologyThermal-magnetic
Trip unit protection functionsLI
Control typeToggle
Circuit breaker mounting modeFixed
Complementary
[Ui] rated insulation voltage440 V AC conforming to EN/IEC 60947-2
[Uimp] rated impulse withstand voltage8 kV conforming to EN/IEC 60947-2
[Ics] rated service short-circuit breaking capacity70 kA at 380/415 V AC 50/60 Hz conforming to EN/IEC 60947-2
80 kA at 220/230 V AC 50/60 Hz conforming to EN/IEC 60947-2
Mechanical durability15000 cycles
Electrical durability3000 cycles at 415 V In
Power dissipation per pole60 W
Mounting supportBackplate
Mounting positionHorizontal and vertical
Flat on the back
Upside connectionFront
Downside connectionFront
Connection terminalsscrew terminals
Connection pitch60 mm
Protection typeL : for overload protection (thermal)
I : for short-circuit protection (magnetic)
Trip unit rating500 A at 40 °C
Long-time pick-up adjustment type Ir (thermal protection)Adjustable
[Ir] long-time protection pick-up adjustment range0.7...1 x In
Long-time protection delay adjustment type trFixed
Instantaneous protection pick-up adjustment type IiFixed
[Ii] instantaneous protection pick-up adjustment range12 x In
Width (W)180 mm
Height (H)250 mm
Depth (D)105 mm
Net weight6.9 kg
ColourGrey (RAL 7035)
Environment
StandardsEN/IEC 60947-1
EN/IEC 60947-2
EN/IEC 60947-2 Annex H
Overvoltage categoryIII
Pollution degree3 conforming to IEC 60664-1
IP degree of protectionIP20 conforming to IEC 60529
Ambient air temperature for operation-20…55 °C
Ambient air temperature for storage-35…85 °C
Operating altitude0...2000 m without derating
2000...5000 m with derating
Packing Units
Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height18 cm
Package 1 Width27 cm
Package 1 Length29 cm
Package 1 Weight11050 g
Unit Type of Package 2P06
Number of Units in Package 212
Package 2 Height105 cm
Package 2 Width60 cm
Package 2 Length80 cm
Package 2 Weight146.392 kg