บริษัท ทริปเปิ้ล อี เทรดดิ้ง จำกัด

LC1E200M5 Product picture Schneider Electric EasyTeSys Contactors technical unique selling points E

฿5092.00
EasyPact TVS contactor 3 poles for motor applications up to 200A 100kW@440V. It provides a 220V 50Hz AC coil, without built-in auxiliary contacts, power and control connections by screw clamp termin
เหลือ 100 ชิ้น
ซื้อเลย
หยิบลงตะกร้า
  • หมวดหมู่ : SCHNEIDER
  • รหัสสินค้า : SC-000241

รายละเอียดสินค้า LC1E200M5 Product picture Schneider Electric EasyTeSys Contactors technical unique selling points E

Main
RangeEasy TeSys
Range of productEasy TeSys Control
Product or component typeContactor
Device short nameLC1E
Contactor applicationMotor control
Resistive load
Utilisation categoryAC-3
AC-3e
AC-1
Poles description3P
[Ue] rated operational voltagePower circuit: <= 690 V AC 50/60 Hz
[Ie] rated operational current200 A (at <55 °C) at <= 440 V AC AC-3 for power circuit
175 A (at <55 °C) at <= 440 V AC AC-3e for power circuit
250 A (at <40 °C) at <= 440 V AC AC-1 for power circuit
[Uc] control circuit voltage220 V AC 50 Hz
Complementary
Motor power kW55 kW at 220...230 V AC 50/60 Hz
90 kW at 380...400 V
100 kW at 415 V
100 kW at 440 V
110 kW at 500 V
110 kW at 660...690 V
Pole contact composition3 NO
[Ith] conventional free air thermal current250 A (at 40 °C) for power circuit
Irms rated making capacity2000 A at 440 V AC for power circuit conforming to IEC 60947-4-1
Rated breaking capacity1600 A at 440 V for power circuit conforming to IEC 60947
[Icw] rated short-time withstand current1500 A 40 °C - 10 s for power circuit
Associated fuse rating10 A gG at <= 690 V coordination type 1 for control circuit conforming to IEC 60947-5-1
315 A gG at <= 690 V coordination type 1 for power circuit
Average impedance0.33 mOhm - Ith 250 A 50 Hz for power circuit
Power dissipation per pole13 W AC-3
21 W AC-1
[Ui] rated insulation voltage690 V conforming to IEC 60947-4-1
Overvoltage categoryIII
Pollution degree3
[Uimp] rated impulse withstand voltage8 kV coil not connected to the power circuit conforming to IEC 60947
Mechanical durability5000000 cycles
Electrical durability500000 cycles AC-3
200000 cycles AC-1
Control circuit typeAC at 50 Hz
Control circuit voltage limits0.85...1.1 Uc (-5…55 °C):operational 50 Hz
0.35...0.55 Uc (-5…55 °C):drop-out 50 Hz
Inrush power in VA805 VA 50 Hz cos phi 0.3 (at 20 °C)
970 VA 60 Hz cos phi 0.3 (at 20 °C)
Hold-in power consumption in VA55 VA 50 Hz cos phi 0.3 (at 20 °C)
66 VA 60 Hz cos phi 0.3 (at 20 °C)
Heat dissipation18…24 W for control circuit
Operating time20...35 ms on closing
7...15 ms on opening
Maximum operating rate1200 cyc/h 55 °C
Connections - terminalsControl circuit: screw clamp terminals 1 1…4 mm² - cable stiffness: flexible without cable end
Control circuit: screw clamp terminals 2 1…4 mm² - cable stiffness: flexible without cable end
Control circuit: screw clamp terminals 2 1…2.5 mm² - cable stiffness: flexible with cable end
Control circuit: screw clamp terminals 1 1…4 mm² - cable stiffness: solid without cable end
Control circuit: screw clamp terminals 2 1…4 mm² - cable stiffness: solid without cable end
Control circuit: screw clamp terminals 1 1…2.5 mm² - cable stiffness: flexible with cable end
Power circuit: cable with lug - external diameter: 150 mm
Power circuit: bars 2 - busbar cross section: 3 x 25 mm
Tightening torqueControl circuit: 1.2 N.m
Power circuit: 18 N.m
Minimum switching voltage17 V for control circuit
Minimum switching current5 mA for control circuit
Insulation resistance> 10 MOhm for control circuit
Non-overlap time1.5 ms on energisation guaranteed between NC and NO contact
1.5 ms on de-energisation guaranteed between NC and NO contact
Mounting supportPlate
Environment
StandardsIEC 60947-1
IEC 60947-4-1
IEC 60947-5-1
Product certificationsEAC
CE
IP degree of protectionIP2X conforming to IEC 60529
Protective treatmentTH (pollution degree 3) conforming to IEC 60068-2-30 test Db
Permissible ambient air temperature around the device-20…70 °C at Uc
-60…80 °C storage
-5…55 °C operation
Operating altitude3000 m without derating
Fire resistance850 °C conforming to IEC 60695-2-1
Mechanical robustnessVibrations contactor open (1.5 Gn, 5...300 Hz)
Vibrations contactor closed (3 Gn, 5...300 Hz)
Shocks contactor open (6 Gn for 11 ms)
Shocks contactor closed (7 Gn for 11 ms)
Height174 mm
Width168.5 mm
Depth181 mm
Net weight4.6 kg
Packing Units
Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height22.000 cm
Package 1 Width22.500 cm
Package 1 Length23.500 cm
Package 1 Weight4.999 kg
Unit Type of Package 2S06
Number of Units in Package 212
Package 2 Height75.000 cm
Package 2 Width60.000 cm
Package 2 Length80.000 cm
Package 2 Weight64.000 kg
Contractual warranty
Warranty18 months