บริษัท ทริปเปิ้ล อี เทรดดิ้ง จำกัด

Contactor,Easy TeSys Control,LC1E,3P(3NO),AC-3,<=440V,400A,220V AC coil LC1E400M7

฿13224.00
Easy TeSys Control contactor 3 poles for motor applications up to 400A 250kW@440V. It provides a 220V 50/60Hz AC coil, without built-in auxiliary contacts, power and control connections by screw clamp
เหลือ 100 ชิ้น
ซื้อเลย
หยิบลงตะกร้า
  • หมวดหมู่ : SCHNEIDER
  • รหัสสินค้า : SC-000244

รายละเอียดสินค้า Contactor,Easy TeSys Control,LC1E,3P(3NO),AC-3,<=440V,400A,220V AC coil LC1E400M7

Main
RangeEasy TeSys
Range of productEasy TeSys Control
Product or component typeContactor
Device short nameLC1E
Contactor applicationMotor control
Resistive load
Utilisation categoryAC-3
AC-3e
AC-1
Poles description3P
[Ue] rated operational voltagePower circuit: <= 690 V AC 50/60 Hz
[Ie] rated operational current400 A (at <55 °C) at <= 440 V AC AC-3 for power circuit
330 A (at <55 °C) at <= 440 V AC AC-3e for power circuit
500 A (at <40 °C) at <= 440 V AC AC-1 for power circuit
[Uc] control circuit voltage220 V AC 50/60 Hz
Complementary
Motor power kW110 kW at 220...230 V AC 50/60 Hz
200 kW at 380...400 V
220 kW at 415 V
250 kW at 440 V
257 kW at 500 V
280 kW at 660...690 V
Pole contact composition3 NO
[Ith] conventional free air thermal current500 A (at 40 °C) for power circuit
Irms rated making capacity4000 A at 440 V AC for power circuit conforming to IEC 60947-4-1
Rated breaking capacity3200 A at 440 V for power circuit conforming to IEC 60947
[Icw] rated short-time withstand current3600 A 40 °C - 10 s for power circuit
Associated fuse rating10 A gG at <= 690 V coordination type 1 for control circuit conforming to IEC 60947-5-1
630 A gG at <= 690 V coordination type 1 for power circuit
Average impedance0.26 mOhm - Ith 500 A 50 Hz for power circuit
Power dissipation per pole42 W AC-3
65 W AC-1
[Ui] rated insulation voltage690 V conforming to IEC 60947-4-1
Overvoltage categoryIII
Pollution degree3
[Uimp] rated impulse withstand voltage8 kV coil not connected to the power circuit conforming to IEC 60947
Mechanical durability4000000 cycles
Electrical durability250000 cycles AC-1
600000 cycles AC-3
Control circuit typeAC at 50/60 Hz
Control circuit voltage limits0.85...1.1 Uc (-5…55 °C):operational 50/60 Hz
0.35...0.5 Uc (-5…55 °C):drop-out 50/60 Hz
Inrush power in VA1075 VA 50 Hz cos phi 0.9 (at 20 °C)
1075 VA 60 Hz cos phi 0.9 (at 20 °C)
Hold-in power consumption in VA15 VA 50 Hz cos phi 0.9 (at 20 °C)
15 VA 60 Hz cos phi 0.9 (at 20 °C)
Heat dissipation14 W for control circuit
Operating time100...170 ms on opening
40...75 ms on closing
Maximum operating rate2400 cyc/h 55 °C
Connections - terminalsControl circuit: screw clamp terminals 1 1…4 mm² - cable stiffness: flexible without cable end
Control circuit: screw clamp terminals 2 1…4 mm² - cable stiffness: flexible without cable end
Control circuit: screw clamp terminals 1 1…4 mm² - cable stiffness: flexible with cable end
Control circuit: screw clamp terminals 2 1…2.5 mm² - cable stiffness: flexible with cable end
Control circuit: screw clamp terminals 1 1…4 mm² - cable stiffness: solid without cable end
Control circuit: screw clamp terminals 2 1…4 mm² - cable stiffness: solid without cable end
Power circuit: cable with lug 2 - external diameter: 150 mm
Power circuit: bars 2 - busbar cross section: 30 x 5 mm
Tightening torqueControl circuit: 1.2 N.m
Power circuit: 35 N.m
Minimum switching voltage17 V for control circuit
Minimum switching current5 mA for control circuit
Insulation resistance> 10 MOhm for control circuit
Non-overlap time1.5 ms on energisation guaranteed between NC and NO contact
1.5 ms on de-energisation guaranteed between NC and NO contact
Mounting supportPlate
Environment
StandardsIEC 60947-4-1
IEC 60947-5-1
IEC 60947-1
Product certificationsEAC
CE
IP degree of protectionIP00 conforming to IEC 60529
Permissible ambient air temperature around the device-20…70 °C at Uc
-60…80 °C storage
-5…55 °C operation
Operating altitude3000 m without derating
Fire resistance850 °C conforming to IEC 60695-2-1
Mechanical robustnessVibrations contactor open (1.5 Gn, 5...300 Hz)
Shocks contactor open (6 Gn for 11 ms)
Vibrations contactor closed (5 Gn, 5...300 Hz)
Shocks contactor closed (15 Gn for 11 ms)
Height375 mm
Width213 mm
Depth219 mm
Net weight9.1 kg
Packing Units
Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height26.000 cm
Package 1 Width24.000 cm
Package 1 Length32.000 cm
Package 1 Weight9.329 kg
Unit Type of Package 2S06
Number of Units in Package 210
Package 2 Height75.000 cm
Package 2 Width60.000 cm
Package 2 Length80.000 cm
Package 2 Weight106.290 kg