บริษัท ทริปเปิ้ล อี เทรดดิ้ง จำกัด

Contactor,Easy TeSys Control,LC1E,3P(3NO),AC-3,<=440V,630A,220V AC coil LC1E630M7

฿29336.00
Easy TeSys Control contactor 3 poles for motor applications up to 630A 400kW@440V. It provides a 220V 50/60Hz AC coil, without built-in auxiliary contacts, power and control connections by screw cla
เหลือ 100 ชิ้น
ซื้อเลย
หยิบลงตะกร้า
  • หมวดหมู่ : SCHNEIDER
  • รหัสสินค้า : SC-0000246

รายละเอียดสินค้า Contactor,Easy TeSys Control,LC1E,3P(3NO),AC-3,<=440V,630A,220V AC coil LC1E630M7

Main
RangeEasy TeSys
Range of productEasy TeSys Control
Product or component typeContactor
Device short nameLC1E
Contactor applicationMotor control
Resistive load
Utilisation categoryAC-3
AC-3e
AC-1
Poles description3P
[Ue] rated operational voltagePower circuit: <= 690 V AC 50/60 Hz
[Ie] rated operational current630 A (at <55 °C) at <= 440 V AC AC-3 for power circuit
500 A (at <55 °C) at <= 440 V AC AC-3e for power circuit
1000 A (at <40 °C) at <= 440 V AC AC-1 for power circuit
[Uc] control circuit voltage220 V AC 50/60 Hz
Complementary
Motor power kW185 kW at 220...230 V AC 50/60 Hz
335 kW at 380...400 V
375 kW at 415 V
400 kW at 440 V
400 kW at 500 V
450 kW at 660...690 V
Pole contact composition3 NO
[Ith] conventional free air thermal current1000 A (at 40 °C) for power circuit
Irms rated making capacity6300 A at 440 V AC for power circuit conforming to IEC 60947-4-1
Rated breaking capacity5040 A at 440 V for power circuit conforming to IEC 60947
[Icw] rated short-time withstand current5050 A 40 °C - 10 s for power circuit
Associated fuse rating10 A gG at <= 690 V coordination type 1 for control circuit conforming to IEC 60947-5-1
800 A gG at <= 690 V coordination type 1 for power circuit
Average impedance0.12 mOhm - Ith 1000 A 50 Hz for power circuit
Power dissipation per pole48 W AC-3
120 W AC-1
[Ui] rated insulation voltage690 V conforming to IEC 60947-4-1
Overvoltage categoryIII
Pollution degree3
[Uimp] rated impulse withstand voltage8 kV coil not connected to the power circuit conforming to IEC 60947
Mechanical durability4000000 cycles
Electrical durability200000 cycles AC-1
600000 cycles AC-3
Control circuit typeAC at 50/60 Hz
Control circuit voltage limits0.85...1.1 Uc (-5…55 °C):operational 50/60 Hz
0.25...0.5 Uc (-5…55 °C):drop-out 50/60 Hz
Inrush power in VA1650 VA 50 Hz cos phi 0.9 (at 20 °C)
1650 VA 60 Hz cos phi 0.9 (at 20 °C)
Hold-in power consumption in VA22 VA 50 Hz cos phi 0.9 (at 20 °C)
22 VA 60 Hz cos phi 0.9 (at 20 °C)
Heat dissipation20 W for control circuit
20 W
Operating time40...80 ms on closing
100...200 ms on opening
Maximum operating rate1200 cyc/h 55 °C
Connections - terminalsControl circuit: screw clamp terminals 1 1…4 mm² - cable stiffness: flexible without cable end
Control circuit: screw clamp terminals 2 1…4 mm² - cable stiffness: flexible without cable end
Control circuit: screw clamp terminals 1 1…4 mm² - cable stiffness: flexible with cable end
Control circuit: screw clamp terminals 2 1…2.5 mm² - cable stiffness: flexible with cable end
Control circuit: screw clamp terminals 1 1…4 mm² - cable stiffness: solid without cable end
Control circuit: screw clamp terminals 2 1…4 mm² - cable stiffness: solid without cable end
Power circuit: cable with lug 2
Power circuit: bars 2 - busbar cross section: 60 x 5 mm
Tightening torqueControl circuit: 1.2 N.m
Power circuit: 58 N.m
Minimum switching voltage17 V for control circuit
Minimum switching current5 mA for control circuit
Insulation resistance> 10 MOhm for control circuit
Non-overlap time1.5 ms on energisation guaranteed between NC and NO contact
1.5 ms on de-energisation guaranteed between NC and NO contact
Mounting supportPlate
Environment
StandardsIEC 60947-5-1
IEC 60947-4-1
IEC 60947-1
Product certificationsEAC
CE
IP degree of protectionIP00 conforming to IEC 60529
Permissible ambient air temperature around the device-20…70 °C at Uc
-60…80 °C storage
-5…55 °C operation
Operating altitude3000 m without derating
Fire resistance850 °C conforming to IEC 60695-2-1
Mechanical robustnessShocks contactor open (6 Gn for 11 ms)
Shocks contactor closed (15 Gn for 11 ms)
Vibrations contactor open (2 Gn, 5...300 Hz)
Vibrations contactor closed (4 Gn, 5...300 Hz)
Height304 mm
Width309 mm
Depth255 mm
Net weight18.6 kg
Packing Units
Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height30.000 cm
Package 1 Width46.500 cm
Package 1 Length36.500 cm
Package 1 Weight18.847 kg
Unit Type of Package 2P06
Number of Units in Package 24
Package 2 Height75.000 cm
Package 2 Width60.000 cm
Package 2 Length80.000 cm
Package 2 Weight83.888 kg